pH/ORP storage solution
KCl solution for pH and ORP electrode storage and regeneration
- 3 mol/L potassium chloride (3 M KCl) liquid
- 100 ml and 1 L containers
pH/ORP storage solution
KCl solution for pH and ORP electrode storage and regeneration
- 3 mol/L potassium chloride (3 M KCl) liquid
- 100 ml and 1 L containers
Просмотр
The 3 M potassium chloride (KCl) solution is a storage and regeneration solution to keep the electrodes of KROHNE SMARTPAT and OPTISENS pH sensors and ORP sensors from drying out and to extend sensor lifetime. It is available in 100 ml and 1 L containers.
Сопутствующие изделия
Water analysis panel
Multi-parameter measuring system for water quality monitoring
- Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
- Installation on compact analytical modules: All measuring points at one location
- Completely pre-wired and pre-assembled for easy bypass installation
SMARTPAT PH 1590
Potentiometric pH sensor for potable, process or treated water applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 2390
Potentiometric pH sensor for municipal and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8150
Potentiometric pH sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
- Glass sensor with open diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8320
Potentiometric pH sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
- Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8530
Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
- Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8570
Potentiometric pH sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
- Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT ORP 1590
Potentiometric ORP sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- -1500…+1500 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
- Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8150
Potentiometric ORP sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
- Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8510
Potentiometric ORP sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
- Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor
OPTISENS PH 8100
Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
- Glass sensor with 2 open diaphragms and Pt100 for temperature compensation
OPTISENS PH 8300
Potentiometric pH sensor for wastewater, surface and process water applications
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
- Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8390
Potentiometric pH sensor for municipal and industrial wastewater applications
- For use with analytical transmitter
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation
OPTISENS PH 8500
Potentiometric pH sensor for potable water applications
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
- Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8590
Potentiometric pH sensor for water and wastewater applications
- For use with analytical transmitter
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation
OPTISENS PH 9100
Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
- Liquid electrolyte glass sensor with open glass sleeve diaphragm
OPTISENS PH 9500
Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
- Liquid electrolyte glass sensor with 3 ceramic diaphragms
OPTISENS ORP 8500
Potentiometric ORP sensor for water and wastewater applications
- For use with analytical transmitter
- Process connection: PG13.5
- -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
- Glass sensor with platinum electrode and ceramic diaphragm
OPTISENS ORP 8590
Potentiometric ORP sensor for water and wastewater applications
- For use with analytical transmitter
- Process connection: ¾ NPT (male)
- -2000…+2000 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
- Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt100 temperature sensor